Bitumen is ‘cutback’ by adding controlled amounts of petroleum distillates such as kerosene. This is done to reduce the viscosity of the bitumen temporarily so it can penetrate pavements more effectively or to allow spraying at temperatures that are too cold for successful sprayed sealing with neat bitumen. The materials used to cutback bitumen will evaporate after application to leave the remaining material similar in hardness to the original bitumen.ApplicationPriming and Tack Coating The process of priming involves applying a low viscosity binder to a prepared but usually unbound aggregate base. It is intended to be absorbed by the top layers of the base and provide a surface more easily ‘wetted’ by a subsequent bituminous covering. The primer will be able to carry traffic for a short time (although this practice is uncommon) and help control dust. Generally, primers are applied at rates between 0.5 and 1.4 L/m2 . Cutback bitumens suitable for priming are also used for tack coats, which are applied to an underlying surface to help with the adhesion of subsequent asphalt layer. A typical application rate is between 0.2 and 0.4 L/m2.
MC- 30
Cutback Bitumen |
|
|
|
Type : Medium-Curing |
|
|
|
Grade : MC-30 |
|
|
|
Standard : ASTM D 2027 |
|
|
|
Property Min Max Test Method |
Min |
Max |
Test Method |
Kinematic viscosity at 60°C mm2/s |
30 |
60 |
ASTM D2170 |
Flash Point (Tag Open-Cup), °C |
38 |
_ |
ASTM D3143 |
Distillate test: |
|
|
|
Distillate, volume percent of total Distillate to 360°C: |
|
|
|
To 225°C |
_ |
25 |
ASTM D402 |
To 260°C |
40 |
70 |
ASTM D402 |
To 316°C |
75 |
93 |
ASTM D402 |
Residue from distillation to 360°C, |
|
|
|
percent volume by difference |
50 |
_ |
ASTM D402 |
Tests on residue from distillation: |
|
|
|
Viscosity at 60 °C, |
30 |
120 |
ASTM D2170 |
Penetration at 25 °C, |
120 |
250 |
ASTM D5 |
Ductility at 25 °C, |
100 |
_ |
ASTM D113 |
Solubility in trichloroethylene, % |
99 |
_ |
ASTM D2042 |
Water, % |
_ |
0,2 |
ASTM D95 |
Cutback Bitumen |
|
|
|
Type : Medium-Curing |
|
|
|
Grade : MC-70 |
|
|
|
Standard : ASTM D 2027 |
|
|
|
Property Min Max Test Method |
Min |
Max |
Test Method |
Kinematic viscosity at 60°C mm2/s |
70 |
140 |
ASTM D2170 |
Flash Point (Tag Open-Cup), °C |
38 |
_ |
ASTM D3143 |
Distillate test: |
|
|
|
Distillate, volume percent of total Distillate to 360°C: |
|
|
|
To 225°C |
_ |
20 |
ASTM D402 |
To 260°C |
20 |
60 |
ASTM D402 |
To 316°C |
65 |
90 |
ASTM D402 |
Residue from distillation to 360°C, |
|
|
|
percent volume by difference |
55 |
_ |
ASTM D402 |
Tests on residue from distillation: |
|
|
|
Viscosity at 60 °C, |
30 |
120 |
ASTM D2170 |
Penetration at 25 °C, |
120 |
250 |
ASTM D5 |
Ductility at 25 °C, |
100 |
_ |
ASTM D113 |
Solubility in trichloroethylene, % |
99 |
_ |
ASTM D2042 |
Water, % |
_ |
0,2 |
ASTM D95 |
MC- 70
Cutback Bitumen |
|
|
|
Type : Medium-Curing |
|
|
|
Grade : MC-250 |
|
|
|
Standard : ASTM D 2027 |
|
|
|
Property Min Max Test Method |
Min |
Max |
Test Method |
Kinematic viscosity at 60°C mm2/s |
250 |
500 |
ASTM D2170 |
Flash Point (Tag Open-Cup), °C |
66 |
_ |
ASTM D3143 |
Distillate test: |
|
|
|
Distillate, volume percent of total Distillate to 360°C: |
|
|
|
To 225°C |
_ |
10 |
ASTM D402 |
To 260°C |
15 |
55 |
ASTM D402 |
To 316°C |
60 |
87 |
ASTM D402 |
Residue from distillation to 360°C, |
|
|
|
percent volume by difference |
67 |
_ |
ASTM D402 |
Tests on residue from distillation: |
|
|
|
Viscosity at 60 °C, |
30 |
120 |
ASTM D2170 |
Penetration at 25 °C, |
120 |
250 |
ASTM D5 |
Ductility at 25 °C, |
100 |
_ |
ASTM D113 |
Solubility in trichloroethylene, % |
99 |
_ |
ASTM D2042 |
Water, % |
_ |
0,2 |
ASTM D95 |
MC- 250
Cutback Bitumen |
|
|
|
Type : Medium-Curing |
|
|
|
Grade : MC-800 |
|
|
|
Standard : ASTM D 2027 |
|
|
|
Property Min Max Test Method |
Min |
Max |
Test Method |
Kinematic viscosity at 60°C mm2/s |
800 |
1600 |
ASTM D2170 |
Flash Point (Tag Open-Cup), °C |
66 |
_ |
ASTM D3143 |
Distillate test: |
|
|
|
Distillate, volume percent of total Distillate to 360°C: |
|
|
|
To 225°C |
_ |
_ |
ASTM D402 |
To 260°C |
_ |
35 |
ASTM D402 |
To 316°C |
45 |
80 |
ASTM D402 |
Residue from distillation to 360°C, |
|
|
|
percent volume by difference |
75 |
_ |
ASTM D402 |
Tests on residue from distillation: |
|
|
|
Viscosity at 60 °C, |
30 |
120 |
ASTM D2170 |
Penetration at 25 °C, |
120 |
250 |
ASTM D5 |
Ductility at 25 °C, |
100 |
_ |
ASTM D113 |
Solubility in trichloroethylene, % |
99 |
_ |
ASTM D2042 |
Water, % |
_ |
0,2 |
ASTM D95 |
MC- 800
Cutback Bitumen |
|
|
|
Type : Medium-Curing |
|
|
|
Grade : MC-3000 |
|
|
|
Standard : ASTM D 2027 |
|
|
|
Property Min Max Test Method |
Min |
Max |
Test Method |
Kinematic viscosity at 60°C mm2/s |
3000 |
6000 |
ASTM D2170 |
Flash Point (Tag Open-Cup), °C |
66 |
_ |
ASTM D3143 |
Distillate test: |
|
|
|
Distillate, volume percent of total Distillate to 360°C: |
|
|
|
To 225°C |
_ |
_ |
ASTM D402 |
To 260°C |
_ |
15 |
ASTM D402 |
To 316°C |
15 |
75 |
ASTM D402 |
Residue from distillation to 360°C, |
|
|
|
percent volume by difference |
80 |
_ |
ASTM D402 |
Tests on residue from distillation: |
|
|
|
Viscosity at 60 °C, |
30 |
120 |
ASTM D2170 |
Penetration at 25 °C, |
120 |
250 |
ASTM D5 |
Ductility at 25 °C, |
100 |
_ |
ASTM D113 |
Solubility in trichloroethylene, % |
99 |
_ |
ASTM D2042 |
Water, % |
_ |
0,2 |
ASTM D95 |
MC- 3000